Room thermostat for the control of heating applications in apartments, single family homes, dormitories
and other residential-type as well as light commercial spaces. With remote access via computer, tablet,
or smartphone using the Siemens Comfort Cloud service.
Room thermostat features
• Backlit, auto-dimming 90 mm color LCD touch screen for intuitive local operation
• Mobile app for smartphones
• Air quality indication via built-in sensor
• Operate automatically following a scheduler
• Direct temperature and operating mode selection
• RoomOptiControl function with Green leaf button for energy-optimized operation
• Temperature setting limitation for use in public spaces
• Screen lock protection against unauthorized access
• Manual switchover between "Home", "Away" and "OFF" on touch screen
• Room temperature control using the built-in temperature sensor or an optional remote sensor
• Optional temperature averaging using an additional remote temperature sensor
• Patented self-learning algorithm with PID response (patent pending) guaranteeing optimum temperature control performance in all room types
• Optimum start control function that advances the switch-on time to ensure the selected setpoint is reached as required
• Floor temperature limitation using a remote sensor in electric floor-heating applications
• Humidity control using the built-in humidity sensor or an optional remote sensor
• Presence detection using a built-in PIR sensor or approach sensor
• Two multifunctional inputs, optional and configurable for operating mode switchover contact (e.g. window contact), remote room temperature sensor, floor temperature sensor, outside air temperature sensor, remote humidity sensor
• Two relay outputs for heating equipment, extra output for domestic hot water (DHW) boiler, humidifier or dehumidifier
• Periodic pump/valve operation to protect against seizing
• Navigation wizard for guided, fast commissioning
• Remote firmware upgrade capability
Remote operation and monitoring
• Mobile App for smartphones and tablets based on iOS and Android
• Individual time program for each day of the week
• Energy consumption indication
• Manual switchover between “Home”, “Away” and “OFF” operating modes on mobile app
• Individual scheduler for domestic hot water boiler
• User account management
RDG100KN Room thermostat
X
RDG100KN Room thermostat
Room thermostat with KNX communications, AC 230 V, for fan coil units and universal applications
• KNX communications
• 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Operating modes: Comfort, Economy and Protection
• 2-position, 3-position or PWM control outputs
• Automatic or manual fan speed for 1-speed, 3-speed fan
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 4-pipe system with electrical heater
• 2-stage heating or cooling system
RDG160KN Room thermostat
X
RDG160KN Room thermostat
Room thermostat with KNX communications, AC 24 V, for fan coil units and universal applications, heat pump, fan (1-/ 3-speed, DC), valves (2-point, DC)
• KNX communications
• For applications with DC control outputs and DC or 3-speed fan output
• For applications with 2-position control output with DC fan output
• 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
• Operating modes: Comfort, Economy and Protection
• Automatic or manual EC fan or 1-/3-speed
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Backlit display
• Master / Slave function in KNX S-mode
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 2-stage heating or cooling system
• Heating / cooling with 6-port ball valves
RDF800KN/NF Touch screen room thermostat
X
RDF800KN/NF Touch screen room thermostat
Touch screen room thermostat with KNX communications, for 2-/4- pipe fan coil, universal applications or compressors in DX-type equipment (for China frames)
• KNX communications
• Operating modes: Comfort, Economy and Protection
• For heating and/or cooling applications
• 2 or 3-position control outputs
• Output for 1-speed or 3-speed fan
• 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: Ivory white
• Backlit display
• Mounting on chinese mounting frames
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF800KN KNX Room Temp Controller
X
RDF800KN KNX Room Temp Controller
Touch screen room thermostat with KNX communications, for 2-/4- pipe fan coil, universal applications or compressors in DX-type equipment
• KNX communications
• Operating modes: Comfort, Economy and Protection
• For heating and/or cooling applications
• 2 or 3-position control outputs
• Output for 1-speed or 3-speed fan
• 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: Ivory white
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF600KN KNX Room Controller
X
RDF600KN KNX Room Controller
Flush-mount room thermostat with KNX communications, 2-/4-pipe fan coils or DX type equipment
Flush-mount room thermostat with LCD for fan coil units and compressors in DX-type equipment
• KNX communications
• For heating and/or cooling applications
• 2 or 3-position control outputs
• Output for 1-speed or 3-speed fan
• 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
• Operating modes: Comfort, Economy and Protection
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Backlit display
• Color of housing: signal white (RAL 9003)
• Independent function for window contact, presence detector (standard presence and hotel presence)
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF302 FCU controller with mod-bus communication
X
RDF302 FCU controller with mod-bus communication
Flush-mount room thermostat for rectangular conduit box with Modbus communications, 2-/4-pipe fan coils or DX type equipment
• Modbus communications
• For heating and/or cooling applications
• 2 or 3-position control outputs
• Output for 1-speed or 3-speed fan
• 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Operating modes: Comfort, Economy and Protection
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: signal white (RAL 9003)
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDG405KN Room Thermostat
X
RDG405KN Room Thermostat
Room thermostat for temperature and air quality control with KNX communications, AC 24 V, VAV heating and cooling systems
• KNX communications
• Output DC 0…10 V for VAV actuator and auxiliary output ON/OFF, PWM or 3-position or 3-position for VAV actuator and auxiliary output DC 0...10 V
• 2 multifunctional inputs for keycard contact, external room / return air temperature (1x, QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
• 1 input DC 0...10 V for damper position feedback, for CO2 sensor
• Operating modes: Comfort, Economy and Protection
• Modulating PI control
• Control depending on the room or the return air temperature and air quality
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Minimum and maximum limitation of air flow signal
• Output signal inversion (DC 0...10 V) as an option
• Backlit display
Application selectable:
• Single-duct system
• Single-duct system with electrical heater
• Single-duct system and radiator / floor heating
• Single-duct system with heating / cooling coil
RAA11 Room Thermostat
X
RAA11 Room Thermostat
Electromechanical room thermostat, public sector model
-Heating only or cooling only
-No operating elements on the front of the unit
RAA21 Room Thermostat
X
RAA21 Room Thermostat
Electromechanical room thermostat, basic model
-Heating only or cooling only
-Setpoint adjustment with knob
RAA31 Room Thermostat
X
RAA31 Room Thermostat
Electromechanical room thermostat with on/off switch
-Heating only or cooling only
-Setpoint adjustment with knob
On / off switch
RAA31.16 Room Thermostat
X
RAA31.16 Room Thermostat
Electromechanical room thermostat with on/off switch and LED
Same functionality as RAA31 plus mode indication (red LED, needed AC 230 V)
RAA41 Room Thermostat
X
RAA41 Room Thermostat
Electromechanical room thermostat with selector heating/off/cooling, 1 output
-Heating or cooling
-Setpoint adjustment with knob
-Switch for cooling / off / heating
REV24 Room Thermostat
X
REV24 Room Thermostat
Room thermostat with 2-point control and 7-day time switch, batteries, heating and cooling
-Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large numbers
-Self-learning two-position controller with PID response (patented)
-Operating mode selection:
-7-day automatic mode with max. 3 heating or cooling phases
-Continuous comfort mode
-Continuous energy saving mode
-Protection against frost or overheating
-Exception day (24 hour operation) with max. 3 heating or cooling phases
-A separate temperature setpoint can be entered in automatic mode and for the exception day for each heating or cooling phase
-Control of a heating zone
-Possibility to control cooling equipment
RDD310/EH Heating Thermostat
X
RDD310/EH Heating Thermostat
Flush-mount room thermostat
-Operating voltage AC 230 V
-2-position control with On/Off control output
-Input for cable temperature sensor NTC 3k (QAP1030/UFH) for the floor
-Floor temperature limitation with cable temperature sensor
-Operating modes: Comfort, Energy Saving and Frost Protection
-Minimum and maximum setpoint setting range
-Backlit white LCD
-Protection class IP31, suitable for installation in wet rooms
RDD810/NF Touch screen room thermostat for heating application
X
RDD810/NF Touch screen room thermostat for heating application
-Operating modes: Comfort, Economy and Protection
-Control output: changeover contact (SPDT)
-2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), window contact on/off, presence detector, fault contact, presence detector
-Adjustable commissioning and control parameters
-Minimum and maximum setpoint limitation
-Color of housing: Ivory white
Backlit display
-Mounting on chinese mounting frames
RCC10 Room Thermostat
X
RCC10 Room Thermostat
Room thermostat for 2-pipe fan coils, AC 230 V, positioning signal 2 pt, return air sensor
• Heating or cooling sequence
• Automatic heating/cooling changeover (with sensor QAH11.1)
• Operating mode changeover input for remote control
• Outputs for 3-speed fan (0 / I / II / III)
• 2-position control
• Selectable switching differential (1 K heating, 0.5 K cooling, or 4 K heating, 2 K cooling)
• Input for return temperature sensor (QAH11.1)
• Frost protection mode
RCC20 Room Thermostat
X
RCC20 Room Thermostat
Room thermostat for 2-pipe fan coils, AC 230 V, positioning signal 2 pt, return air sensor, el. heater
• Heating or cooling sequence
• Automatic heating/cooling changeover (with sensor QAH11.1)
• Operating mode changeover input for remote control
• Output for electrical heater
• 2-position control
• Selectable switching differential (1 K heating, 0.5 K cooling, or 4 K heating, 2 K cooling)
• Selectable dead zone (2 K or 5 K)
• Input for return air temperature sensor (QAH11.1)
• Frost protection mode
• Outputs for 3-speed fan (0 / I / II / III)
RAB11.1 Room Thermostat
X
RAB11.1 Room Thermostat
Electromechanical room thermostat for 2-pipe fan coils, selector heating/cooling/fan only
Same functionality and technical data as RAB11. Additional selector position for ventilation (heating and cooling inactive)
RAB21 Room Thermostat
X
RAB21 Room Thermostat
Electromechanical room thermostat for 2-pipe fan coils, basic model
• Heating or cooling applications
• Selector for manual 3-speed fan operation
• Changeover function, heating or cooling (with external automatic aquastat)
• Manual fan operation or automatic fan operation parallel with cooling / heating mode can be configured inside the unit
RDG100 Room Thermostat
X
RDG100 Room Thermostat
Room thermostat, AC 230 V, for fan coil units and universal applications
• Operating modes: Comfort, Energy Saving and Protection
• 2-position, 3-position or PWM control outputs
• Automatic or manual fan speed
• 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 4-pipe system with electrical heater
• 2-stage heating or cooling system
RDG110 Room Thermostat
X
RDG110 Room Thermostat
Room thermostat, AC 230 V, for fan coil units and heat pump applications
• Operating modes: Comfort, Energy Saving and Protection
• 2-position control outputs
• Automatic or manual fan speed
• 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 2-stage heating or cooling system
RDG100T Room Thermostat
X
RDG100T Room Thermostat
Room thermostat, AC 230 V, for fan coil units and universal applications, 7-day time switch, vertical
• Operating modes: Auto timer, Comfort, Energy Saving and Protection
• Auto Timer mode with 8 programmable timers
• 2-position, 3-position or PWM control outputs
• Automatic or manual fan speed for 1-speed or 3-speed fan
• 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Infrared remote control receiver
• Backlit display
• Auto timer can be disabled
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 4-pipe system with electrical heater
• 2-stage heating or cooling system
RDG160T Room Thermostat
X
RDG160T Room Thermostat
Room thermostat, AC 24 V, for fan coil units (3-speed or ECM fan), universal applications and heat pump applications. 7-day time switch. Outputs DC 0..10V or ON/OFF
• Operating modes: Auto timer, Comfort, Energy Saving and Protection
• Auto Timer mode with 8 programmable timers
• 2-position or DC 0...10V control outputs
• ECM fan or 3-speed fan outputs
• Automatic or manual fan speed
• 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, supply air temperature sensor
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Infrared remote control receiver
• Backlit display
• Auto timer can be disabled
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 2-stage heating or cooling system
RDG110U Room Thermostat
X
RDG110U Room Thermostat
Room thermostat, AC 24 V, for fan coil units and heat pump applications
• Operating modes: Comfort, Energy Saving and Protection
• 2-position control outputs
• Automatic or manual fan speed
• 3 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Automatic or manual heating / cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 2-pipe system and radiator / floor heating
• 4-pipe system
• 2-stage heating or cooling system
RDF110 Room Thermostat
X
RDF110 Room Thermostat
Room thermostat for 2-pipe fan coils or DX-type equipment, return air temperature sensor
• Output for an on / off valve actuator or compressor
• Outputs for a 3-speed fan
• Control depending on the room or return air temperature (with sensor QAH11.1)
• 2-position control
• Sensor input either for automatic heating / cooling changeover or return air temperature (with sensor QAH11.1)
• Automatic or manual three-speed fan control
• Operating modes: normal, energy-saving and standby
• Operating mode changeover input for remote control
RDF300.02 Room Thermostat
X
RDF300.02 Room Thermostat
Flush-mount room thermostat for rectangular conduit box, for 2-/4-pipe fan coils or DX type equipment, backlit LCD
Flush-mount room thermostat for rectangular conduit box with LCD for fan coil units and compressors in DX-type equipment
• Output for 3-speed or 1-speed fan
• 2 or 3-position control outputs
• Two multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Operating modes: Comfort, Energy Saving and Protection
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: signal white (RAL 9003)
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF340 Room Thermostat
X
RDF340 Room Thermostat
Flush-mount room thermostat for rectangular conduit box, for 2-/4-pipe fan coils
Flush-mount room thermostat for rectangular conduit box, with LCD for fan coil units
• Output for 3-speed or 1-speed fan
• Two multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Operating modes: Comfort, Energy Saving and Protection
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: signal white (RAL 9003)
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF310.2/MM Room Thermostat
X
RDF310.2/MM Room Thermostat
Flush mount room thermostat for 2-pipe fan coils
Flush-mount room temperature controller with LCD for fan coil units
• Output for on/off valve actuator, 3-wire on/off valve or 1-stage compressor
• 3-speed fan control: Automatic or manual
• Manual heating / cooling changeover or continuous Cooling only / Heating only
• Operation modes: Comfort and Protection
• Adjustable commissioning and control parameters
• Optional display of room temperature or setpoint
• Minimum and maximum setpoint limitation
• Display temperature in increments of 0.5 °C or °F
• Color of housing: signal white (RAL 9003)
RDF600 Room Thermostat
X
RDF600 Room Thermostat
Flush-mount room thermostat for round conduit box for 2-/4-pipe fan coils or DX type equipment, backlit LCD
Flush-mount room thermostat for round conduit box with LCD for fan coil units and compressors in DX-type equipment
• Output for 1-speed or 3-speed fan
• 2 or 3-position control outputs
• Two multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Operating modes: Comfort, Energy Saving and Protection
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: signal white (RAL 9003)
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF600T Room Thermostat
X
RDF600T Room Thermostat
Flush-mount room thermostat for round conduit box, for 2-/4-pipe fan coils or DX type equipment, infrared remote control, 7-day time switch, backlit LCD
Flush-mount room thermostat for round conduit box with LCD for fan coil units and compressors in DX-type equipment
• Output for 1-speed or 3-speed fan
• 2 or 3-position control outputs
• Two multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, operation mode changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact
• Operating modes: Comfort, Energy Saving and Protection
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• With infrared receiver for remote control, remote control not included.
• Color of housing: signal white (RAL 9003)
• 8 Timers with a 7-day programmable schedule
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF510 Room Thermostat
X
RDF510 Room Thermostat
Flush-mount room thermostat for 2-pipe fan coils
Flush-mount thermostat with LCD display for fan coil units
• Output for on/off valve actuator, 3-wire on/off valve
• 3-speed fan control: Automatic or manual
• Manual heating / cooling changeover or continuous Cooling only / Heating only
• Operation modes: Comfort and Protection
• Adjustable commissioning and control parameters
• Optional display of room temperature or setpoint
• Minimum and maximum setpoint limitation
• Display temperature in increments of 0.5 °C or °F
• Color of housing: signal white (RAL 9003)
• LED backlit display
• Full or partial keylock
• Internal sensor calibration
• Timer with delay off function: preset or user selection from 1 to 23 hours
• Return to previous mode or Protection (Off) mode upon power down
• Fan speed low or off in deadzone
• Fan minimum On-time
• Three standard color housings on bulk pack for project delivery
• Customization is also available by request
RDF800 Touch Screen Room Thermostat
X
RDF800 Touch Screen Room Thermostat
Touch screen room thermostat for 2-/4- pipe fan coil, universal applications or compressors in DX-type equipment
• Operating modes: Comfort, Economy and Protection
• For heating and/or cooling applications
• 2 or 3-position control outputs
• Output for 1-speed or 3-speed fan
• 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: Ivory white
• Backlit display
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
RDF800/NF Touch Screen Room Thermostat
X
RDF800/NF Touch Screen Room Thermostat
Touch screen room thermostat for 2-/4- pipe fan coil, universal applications or compressors in DX-type equipment (for China frames)
• Operating modes: Comfort, Economy and Protection
• For heating and/or cooling applications
• 2 or 3-position control outputs
• Output for 1-speed or 3-speed fan
• 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
• Automatic or manual heating/cooling changeover
• Adjustable commissioning and control parameters
• Minimum and maximum setpoint limitation
• Color of housing: Ivory white
• Backlit display
• Mounting on chinese mounting frames
Application selectable:
• 2-pipe system
• 2-pipe system with electrical heater
• 4-pipe system
ARG70.3 Mounting bracket
X
ARG70.3 Mounting bracket
Dimensions (W x H x D)
82 x 82 x 10 mm
ARG70 Mounting Plate
X
ARG70 Mounting Plate
Mounting plate 120 x 120 mm for 4 x 4" housing
Accessories for use with room thermostats RAA.., RAB.., RCC.., RCU.., RDD.., RDE.., RDF..
RAK-TR.1210B-H Thermal Reset Limit Thermostat
X
RAK-TR.1210B-H Thermal Reset Limit Thermostat
Thermal reset limit thermostat, 15..82 °C, protective pocket 100 mm, capillary tube 700 mm, clamping band
External scale, 1 changeover contact, immersion and strap-on thermostat in one.
RAK-TW.1200B-H Thermal Reset Limit Thermostat
X
RAK-TW.1200B-H Thermal Reset Limit Thermostat
Thermal reset limit thermostat, 40...120 °C, protective pocket 100 mm, capillary tube 700 mm, clamping band
Internal scale, 1 changeover contact, immersion and strap-on thermostat in one.
RAK-ST.1430S-M Safety Limit Thermostat
X
RAK-ST.1430S-M Safety Limit Thermostat
Safety temperature limiter fixed 80...100 °C, pocket 100 mm, capillary 700 mm
Internal scale, 1 changeover contact, failsafe capillary, immersion and strap-on thermostat in one, with ambient temperature compensation.
TRG22 Room Thermostat With Helix Sensor
X
TRG22 Room Thermostat With Helix Sensor
Room thermostat with helix sensor, TR -5..50 °C, 2 switches on 2 steps 2..12 K difference
For commercial and industrial applications.
TRG2 Room Thermostat With Helix Sensor
X
TRG2 Room Thermostat With Helix Sensor
Room thermostat with helix sensor, TR -5..50 °C
For commercial and industrial applications.
RXB21.1/FC-10 Room Controller
X
RXB21.1/FC-10 Room Controller
For fan coil units with 3-speed fan.
QAX33.1 Room Unit With Sensor
X
QAX33.1 Room Unit With Sensor
Room unit with sensor, setpoint and operating mode selector, fan speed selection, and PPS2 interface
• Acquisition of room temperature
• Setpoint adjuster for room temperature
• Rocker switch for mode selection (Off/Auto) and for manual fan control with fan coil systems (up to 3 speeds)
QAX34.3 Room Unit With Sensor
X
QAX34.3 Room Unit With Sensor
Room unit with sensor, setpoint and operating mode selector, display and PPS2 interface
• Acquisition of room temperature
• Rocker switch for adjustment of room temperature setpoint
• Rocker switch for mode selection (Off/Auto) and for manual fan control with fan coil systems (up to 3 speeds)
• LCD with display of room temperature and control mode
• Together with the RXB controllers for parameter setting
QAX84.1/PPS2 Room Unit
X
QAX84.1/PPS2 Room Unit
Flush-mounted room unit complete with PPS2 interface and design frame
The set consists of:
• Operator unit,
• PPS2 bus coupling unit and
• Design frame DELTA line in titanium white.
Functionality:
• Acquisition of room temperature
• Switch for adjustment of room temperature setpoint
• Switch for mode selection (Off/Auto) and for manual fan control with fan coil systems (up to 3 speeds)
• LCD with display of room temperature and control mode
Additional functionalities GAMMA
The room unit is complete with Siemens bezel DELTA-i line (titanum white).
About Company
We, QEMQT AL IBDAA REFERIGERATION
TRADING L.L.C. are a onestop purchasing
center for all your HVAC/R needs.We have
ready stock for compressors such as
Mitsubishi, Hitachi, Copeland, Tecumseh,
Aspera, Cubigel,Dorin and so on. We also
provide all kinds of refrigeration parts and
tools. We own complete varieties and
welcome consulting with us about our
products.